Time-of-use battery settings can help a solar-plus-storage system use more of your own electricity and avoid expensive grid imports, but the best schedule depends on your utility tariff, export credit, household demand, weather, and backup needs. This guide explains how to compare those inputs, choose an operating mode, build a charge and discharge schedule, and review the result whenever rates or household loads change.
Overview
A home battery can usually be configured to prioritize one or more goals: storing surplus solar for later use, reducing electricity purchased during expensive periods, exporting energy when export compensation is favorable, or maintaining a reserve for outages. These goals can conflict. For example, keeping a high backup reserve may reduce the energy available for daily bill savings, while discharging aggressively during peak hours may leave less capacity for an evening outage.
Before changing settings, identify four prices or values in your electricity plan:
- Import price: what you pay for electricity during each time period.
- Export credit: what your utility or energy provider credits for electricity sent to the grid.
- Fixed and demand charges: costs that may not be affected directly by battery operation.
- Backup value: the practical importance of keeping energy available during an outage.
Do not assume that the highest-priced period is always the only period that matters. A battery may have a power limit, a usable-capacity limit, conversion losses, and a minimum state of charge. Manufacturer software may also use different names for similar features, such as self-consumption, time-of-use control, peak shaving, reserve, or backup priority. Check the battery and inverter manuals before enabling a schedule.
For broader system planning, pair this guide with a home solar sizing and battery checklist. To assess emergency readiness separately from bill savings, use a solar battery backup test plan.
How to estimate
Start with a simple comparison rather than changing several settings at once. Download or record at least two weeks of interval consumption, solar production, battery state of charge, grid imports, and exports if your monitoring platform provides them. A longer period is useful when weather and occupancy vary.
1. Map the rate periods
Create a table showing the start and end time of each tariff period for weekdays, weekends, and holidays. Mark the periods with the highest import prices. Also record whether the rate schedule changes by season. Utility websites, bills, and customer portals may use different labels, so use the actual rate-plan documentation rather than relying only on an app summary.
2. Estimate the value of one battery cycle
A practical screening formula is:
Potential daily value = discharged energy × avoided import price − charging energy × alternative value
Discharged energy means the energy delivered to your home, not necessarily the battery's advertised nameplate capacity. Charging energy should account for the energy source and the opportunity cost of using it. If the battery charges from solar that would otherwise be exported, the alternative value is the export credit. If it charges from the grid, compare the off-peak import price with the peak price it may avoid. Allow for losses and do not treat the result as a guaranteed saving.
3. Set operating priorities
Choose the priority that matches your objective:
| Mode | Primary goal | Typical approach | Main trade-off |
|---|---|---|---|
| Self-consumption | Use more solar on site | Charge with surplus solar and discharge when the home needs power | May export less energy even when the export credit is attractive |
| Peak shaving | Reduce expensive grid imports | Reserve battery energy for defined high-price or high-demand periods | May leave energy unused if demand is lower than expected |
| Backup priority | Maintain outage readiness | Keep a selected reserve and discharge only above that level | Usually reduces routine bill savings |
4. Build a conservative schedule
For a solar battery time-of-use schedule, allow the battery to charge from solar during the day, then discharge during the periods when grid imports are most costly. If the battery supports grid charging, use it only after comparing the off-peak import price, expected peak price, losses, and any restrictions in the tariff or equipment settings. Set the backup reserve first, then schedule only the capacity above that reserve.
Use the battery's permitted state-of-charge range, maximum charge rate, maximum discharge rate, and temperature limits. Never override a manufacturer's operating limit to pursue a projected saving.
Inputs and assumptions
Record these inputs in a worksheet so you can repeat the estimate after a rate change:
- Usable battery capacity in kilowatt-hours, separate from nameplate capacity.
- Maximum charge and discharge power in kilowatts.
- Round-trip efficiency or the monitoring system's measured charging and discharging losses.
- Current state of charge at the start and end of each relevant period.
- Solar production expected during the charging window.
- Household demand during low-, standard-, and high-price periods.
- Import prices, export credits, fixed charges, and demand charges.
- Minimum backup reserve, such as the percentage selected in the battery app.
- Planned changes, including an electric vehicle, heat pump, water heater, or home occupancy change.
Use a solar forecast cautiously. A schedule based on a clear day may underperform during cloudy weather, while a schedule designed for winter may leave capacity unused in summer. If the system offers weather-aware or forecast-based charging, compare its results with a fixed schedule before deciding which is more reliable for your home.
Export settings deserve special attention. If exported solar receives a relatively strong credit, forcing all available energy into the battery may not improve the bill. Conversely, when export compensation is low, storing surplus solar for later household use may be more valuable. Review your actual bill and interval data using the methods in this solar electricity bill review guide.
Worked examples
Consider a home with a usable battery capacity of 10 kWh, a 20% backup reserve, and a time-of-use plan with a low-price period overnight and a high-price period in the evening. The battery has 8 kWh available above the reserve, before accounting for operating losses. The household typically uses 5 kWh during the evening high-price period and 3 kWh later at night.
Under self-consumption, the system charges from daytime solar and discharges into the home after solar production falls. It may cover the 5 kWh evening load and part of the later load, stopping at the reserve. This is straightforward when the battery is charged by surplus solar and the export credit is modest.
Under peak shaving, the system holds enough energy to cover the high-price window, even if the home imports some electricity during a lower-priced period earlier in the day. If the battery can deliver 5 kWh during the expensive window, the schedule should not discharge the full available balance beforehand. This approach is useful when avoiding high-priced imports is more valuable than maximizing immediate solar use.
Under backup priority, the system maintains the 20% reserve and may use only the remaining energy for daily savings. Before storms, wildfire risk, or other outage concerns, a homeowner might temporarily raise the reserve if the equipment and local conditions make that appropriate. Test the intended backup loads and runtime rather than assuming the reserve will power every circuit; the inverter's output limit and the home's backup wiring matter as much as stored energy.
These examples are decision frameworks, not promised savings. Replace the assumptions with your battery's usable capacity, measured demand, actual tariff, and export rules.
When to recalculate
Review your solar battery charge schedule at least once each billing cycle while you are learning how the system behaves, then revisit it whenever an input changes. Recalculate after a utility rate-plan change, a new export-credit rule, a seasonal tariff transition, or a change in fixed or demand charges. Also review settings after adding an EV charger, heat pump, electric water heater, pool equipment, or other large load.
Use this seasonal checklist:
- Before summer: check whether longer solar-production hours create excess energy and whether evening cooling loads justify preserving more battery capacity.
- Before winter: account for shorter production days, heating loads, lower solar forecasts, and any change in outage priorities.
- Before a tariff change: save the old rate schedule, record the current settings, and compare import prices with export credits.
- Before extreme weather: verify the reserve, backup circuits, communications, and generator or grid interconnection rules where applicable.
- After each review: compare expected and actual imports, exports, state of charge, and bill charges; change one major setting at a time.
Finally, document the date, tariff version, reserve percentage, charge windows, discharge windows, and reason for each change. If the app reports unexpected behavior, pause optimization and check the inverter, battery, and utility documentation or contact a qualified installer. A well-designed schedule is one that improves the intended outcome without compromising equipment limits or the backup protection your household actually needs.